The relay measures the line current from each of the phases and if it exceeds the set threshold, then relay extends a trip signal after an operating time. The relay’s operating time is determined by selecting one of the four inverse time characteristics. The relay has facility to active / inhibit the high set protection feature. The relay output contacts are self reset . Relay operation without any fault current is determined by trip test facility.

Application:

The relay provides time graded phase and earth fault protection of Parallel transformers, Transformer feeders, Parallel feeders, ring main system etc.,

20 in stock

Description

Ratings

Current rating ( In ) 1A / 5A
Aux. Supply 20 to 60V DC
75 to 175V AC / DC
175 to 300V DC
185 to 250V AC

Settings:

Operating characteristics 1) 3.0s Normal Inverse
2) 1.3s Normal Inverse
3) 1.5s Very Inverse
4) 0.8s Extremely Inverse
Phase O/c (IDMT) 50 to 200% in steps of 10%
Earth fault (IDMT) 5 to 80% in steps of 5%
TMS (separate for O/c & E/F) 0.1 to 1.0 in steps of 0.01
Phase Hi-set 200 to 3200% in steps of 200%
Earth fault Hi-set 50 to 800% in steps of 50%

Char. Angel setting

O/C setting Lead 30º
Lead 45º
Lead 60º
E/F setting Lag 12.5º
Lag 30º
Lag 45º

Contacts Durability

Unloaded contact 1,000,000 Operations
Loaded contact 100,000 Operations

Over Load Rating:

Current input 2 times rated continuous 20 times rated for 3s

Burden:

Current input 0.2VA per phase (rated 5A) 0.05VA per phase (rated1A
Aux. Supply Less than 8W (Non operated) Less than 10W (Operated)

Accuracy:

Operating value 105% to 120% of setting
Drop-off / pick-up Between 80% to 95%
Operating Time ±5% or ±30ms whichever is higher
High set operating value ±5% or ±30ms whichever is higher
Phase angle ±9º of the operating angle
High set operating time Less than 30ms @ 2 times current setting
Reset Time 160ms to 180ms

Contact Ratings

Relay rating 10A at 24V DC/230V AC

Mechanical Design :

Weight 2500 gms. (approx)
Case Size 144sq mm, depth 232mm
Installation Flush mounting
Panel cutout 138mm x 138mm

Standard Compliance:

Accuracy test IEC 60255-3
Insulation test IEC 60255-5

Ordering Information

Current rating JRP 011(O/c relay)
JRP 012 (O/c with hiset relay)
JRP 021 (E/F relay)
JRP 022 (E/F with hiset relay)
Current rating 1A / 5A
Auxiliary Supply 20 to 60V DC
75 to 150V AC/ DC
175 to 300V DC / 185 to 250V AC

Reviews

There are no reviews yet.

Be the first to review “PROGRAMMABLE DIRECTIONAL INVERSE TIME CURRENT RELAY JRP 011”

Your email address will not be published. Required fields are marked *

Get a Quick Quote