Description
Ratings
Voltage rating (Un ) |
110V AC 63.5V AC |
Frequency rating |
50Hz |
Aux. Supply |
- 20 to 60V DC
- 75 to 150V AC / DC
- 175 to 300V DC
185 to 250V AC
|
Settings:
Inverse time curve |
- 3 Sec normal inverse curve
- 1.3 Sec normal inverse curve
- Very inverse curve 1.5s
- Extremely inverse curve 0.1s
|
Definite time |
0.1 to 25.0 Sec in steps of 0.1s |
Directional Feature |
Separate Choice of Active / Inhibit mode for over current & Hi-set. |
Characteristic Angle |
Phase – 30°, 45°, and 60° lead E/F – 12.5°, 30° and 45° lag |
Over Current Setting |
Phase – 50 to 200% in steps of 5 % E/F – 5 to 80% in steps of 1% |
TMS |
0.02 to 1.0 in steps of 0.01 (Separate for Phase & E/F) |
Hi-set setting |
Choice of Active / Inhibit Mode Phase – 200 to 3200% in steps of 100% E/F – 50 to 800% in steps of 50% |
Programmable Reset Mode |
Hand / Self Reset |
Mechanical Design :
Weight |
App. 7 Kgs. |
Case Size |
Fascia 152 x 296 mm, Depth 250 mm |
Installation |
Flush mounting |
Panel cutout |
146 x 264 mm |
Standard Compliance :
Accuracy Test |
IEC 60255-3 |
Insulation Test |
IEC 60255-5 |
Accuracy:
Voltage |
±5% |
Operating time |
±5% |
Contact Ratings:
Output contacts |
10A at 24V DC / 230V AC |
Contact Durability :
Loaded contact |
10,000 operations minimum |
Unloaded contact |
100,000 operations minimum |
Over Load Rating:
AC current input |
2 times Rated continuous 20 times Rated for 3 secs. 40 times Rated for 1 sec. |
Burden:
AC voltage input |
0.1VA Per phase (5A Rating) 0.05VA per Phase (1A Rating) |
AC voltage input |
2VA for all phases and E/F |
Aux. Supply |
Less than 4W (Non Operated) Less than 10W (Operated) |
INSULATION
1. 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec . Between all terminals and earth. 2. 1KV RMS, 50 Hz for 1 minute across open contacts.
Ordering Information
Relay type |
JNF 060 |
Voltage rating |
110V or 63.5V |
Aux. Supply |
20 to 60V DC or
75 to 150V AC/ DC or
175 to 300V DC / 185 to 250V AC |
Reviews