SINGLE POLE DEFINITE TIME EARTH FAULT RELAY JRC 012

 0.00

Features

  • Software based design
  • Wide setting range
  • Wide auxiliary supply
  • Low burden

Principle of Operation:

The relay provides earth fault protection for power systems. Relay operating time is determined by set definite time. The relay measures the current from the input CT and if it exceeds the set threshold, it extends a trip signal after the operating time, which is determined by set definite time. The relay output contacts are self reset type. TEST button facilitates testing of relay contacts for trip and alarm circuits.

Application:

The relay provides earth fault protection of Generators, Motors, Transformers, Feeder, etc., and where definite time protection is required.

20 in stock

Description

Ratings

Current rating ( In ) 1A / 5A
Aux. Supply 20 to 60V DC
75 to 175V AC / DC
175 to 300V DC
185 to 250V AC

Settings:

Earth fault setting 5 to 80% in steps of 5 %
Definite time setting 0 to 25s in steps of 0.1s

Over Load Rating:

Current input 2 times rated continuous
20 times rated for 3s
40 times rated for 1s

Burden:

Current input 0.2VA per phase (Rated 5A)
0.05VA per Phase (Rated 1A)
Aux. Supply Less than 3W (Non Operated)
Less than 5W (Operated)

Accuracy:

Operating value ±5%
Operating time ± 5% or ±20ms
Instantaneous time Less than 40ms

Contact Ratings:

Relay rating 10A at 24V DC/230V AC

Contact Durability:

Unloaded contact 1,000,000 Operations
Loaded contact 100,000 Operations

Contact Durability :

Loaded contact 10,000 operations minimum
Unloaded contact 100,000 operations minimum

Insulation

  1. 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec . Between all terminals and cases as per IEC 602555.
  2. 1KV RMS, 50 Hz for 1 minute across open contacts as per IEC 602555

Mechanical Design :

Weight 2000 gms. (approx)
Case Size 144sq mm, depth 232mm
Installation Flush mounting
Panel cutout 138mm x 138mm

Insulation:

  1. 1. 2KV RMS, 50 Hz for 1 minute / 2.5 KV for 1 sec .
  2. Between all terminals and cases .

  3. 1 KV RMS, 50 Hz for 1 minute across open contact

Standard Compliance:

Accuracy test IEC 60255-3
Insulation test IEC 60255-5

Ordering Information

Relay type JRC 012 (E/F)
Current rating 1A / 5A
Auxiliary Supply 20 to 60V DC
75 to 175V AC / DC
175 to 300V DC
185 to 250V AC